Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 16(17)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37687716

RESUMO

As a transfer member at the discontinuous place of vertical load, the deep beam has a complex stress mechanism and many influencing factors, such as compressive strength of concrete, shear span ratio, and reinforcement ratio. At the same time, the stress analysis principle of traditional shallow beams is no longer applicable to the design and calculation of deep-beam structure. The main purpose of this paper was to use the strut-and-tie model to analyze its stress mechanism, and to verify the applicability of the model. Nine high-strength concrete deep-beam specimens with longitudinal reinforcement with an anchor plate of the same size were tested by two-point concentrated loading method. The effects of shear span ratio (0.3, 0.6, and 0.9), longitudinal reinforcement ratio (0.67%, 1.05%, and 1.25%), horizontal reinforcement ratio (0.33%, 0.45%, and 0.50%), and stirrup reinforcement ratio (0.25%, 0.33%, and 0.50%) on the failure mode, deflection curve, characteristic load, crack width, steel bar, and concrete strain of the specimens were analyzed. The results showed that the failure mode of deep-beam specimens was diagonal compression failure. The normal section cracking load was about 15 to 20% of the ultimate load, and the inclined section cracking load was about 30~40% of the ultimate load. The shear span ratio increased from 0.3 to 0.9, and the bearing capacity decreased by 32.9%. When the longitudinal reinforcement ratio increased from 0.67% to 1.25%, the ultimate load increased by 42.6%. The shear span ratio and longitudinal reinforcement ratio have a significant effect on the bearing capacity of the high-strength concrete deep beams with longitudinal reinforcement with an anchor plate. The shear capacity of nine high-strength concrete deep-beam specimens with longitudinal reinforcement with an anchor plate was calculated by national standards, and the results were compared with the calculation results of the Tan-Tang model, the Tan-Cheng model, SSTM, and SSSTM. The analysis showed that the softened strut-and-tie model takes into account the softening effect of compressive concrete, and is a more accurate mechanical model, which can be applied to predict the shear capacity of high-strength concrete deep-beam members with longitudinal reinforcement with an anchor plate.

2.
Materials (Basel) ; 16(14)2023 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-37512182

RESUMO

According to the shear capacity test results of six steel-fiber-reinforced high-strength concrete (SFHSC) corbels with welded-anchorage longitudinal reinforcement under concentrated load, the effects of shear span ratio and steel fiber volume fraction on the failure mode, cracking load and ultimate load of corbel specimens were analyzed. On the basis of experimental research, the shear transfer mechanism of corbel structure was discussed. Then, a modified softened strut-and-tie model (MSSTM), composed of the diagonal and horizontal mechanisms, was proposed, for steel-fiber-reinforced high-strength concrete corbels. The contributions of concrete, steel fiber and horizontal stirrups to the shear bearing capacity of the corbels were clarified. A calculation method for the shear bearing capacity of steel-fiber-reinforced high-strength concrete corbels was established and was simplified on this basis. The calculation results of the model were compared with the test values and calculation results of the GB50010-2010 code, the ACI318-19 code, the EN 1992-1-1 code and the CSA A23.3-19 code. The results showed that the concrete corbel with small shear span ratio mainly has two typical failure modes: shear failure and diagonal compression failure. With the increase in shear span ratio, the shear capacity of corbels decreases. Steel fiber can improve the ductility of a reinforced concrete corbel, but has little effect on the failure mode of the diagonal section. The calculated values of the national codes were lower than the experimental values, and the results were conservative. The theoretical calculation values of the shear capacity calculation model of the corbels were close to the experimental results. In addition, the model has a clear mechanical concept considering the tensile properties of steel-fiber-reinforced high-strength concrete and the influence of horizontal stirrups, which can reasonably reflect the shear transfer mechanism of corbels.

3.
Materials (Basel) ; 16(8)2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37109891

RESUMO

As short cantilever members, corbels are mainly used to transfer eccentric loads to columns. Because of the discontinuity of load and geometric structure, corbels cannot be analyzed and designed using the method based on beam theory. Nine steel-fiber-reinforced high-strength concrete (SFRHSC) corbels were tested. The width of the corbels was 200 mm, the cross-section height of the corbel column was 450 mm, and the cantilever end height was 200 mm. The shear span/depth ratios considered were 0.2, 0.3, and 0.4; the longitudinal reinforcement ratios were 0.55%, 0.75%, and 0.98%; the stirrup reinforcement ratios were 0.39%, 0.52%, and 0.785%; and the steel fiber volume ratios were 0, 0.75%, and 1.5%. According to the test results, this paper discusses the failure process and failure mode of corbel specimens with a small shear span/depth ratio and analyzes the effects of variables such as shear span/depth ratio, longitudinal reinforcement ratio, stirrup reinforcement ratio, and steel fiber volume content on the shear capacity of corbels. The shear capacity of corbels is significantly affected by the shear span/depth ratio, followed by the longitudinal reinforcement ratio and the stirrup reinforcement ratio. Moreover, it is shown that steel fibers have little impact on the failure mode and ultimate load of corbels, but can enhance the crack resistance of corbels. In addition, the bearing capacities of these corbels were calculated by Chinese code GB 50010-2010 and further compared with ACI 318-19 code, EN 1992-1-1:2004 code, and CSA A23.3-19 code, which adopt the strut-and-tie model. The results indicate that the calculation results by the empirical formula in the Chinese code are close to the corresponding test results, while the calculation method based on the strut-and-tie model of a clear mechanical concept yields conservative results, and hence the related parameter values must be further modified.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...